MFM 6100
Two-Phase Mass Flow Meter
The Correflow MFM combines the technology of two patented measurement techniques (velocity and concentration) in a single sensor to achieve a measurement of mass flow. The first measurement determines the two phase slurry velocity and the second measurement determines the fraction of one of the phases of the mixture in relation to the other. Combining these two parameters yields mass per unit time (ie. mass flow).
Two Component Concentrations: 1% to 99%
Materials: Insulating liquids, solids (particulate), gas (bubbles or as carrier)
Typical Response Time: Concentration–updated at 2.5 millisecond intervals using last measured velocity; Velocity–typically updated once per second
Purge Option: Type Z purged (NEMA 4X): Cl1, Div 2, GR C&D
European (Eex approved) housing also available
Sensor: Typical Sensor Pipe sizes: 1/8” (.32 cm) ID or greater
Pressure limits: 1000 psi (69 bar) typical for small sensors, Higher pressure designs available. No moving parts, no flow restrictions or additional pressure drop
Power Requirements: 115 to 240 VAC, 50 to 60 Hz (100 Watts maximum)
Instrument air for optional pressurization(intermittently 4 scfm @ 80 to 120 psi)
Data Analysis Velocity, volume fraction, mass fraction, mass flow measurements on an instantaneous basis and averaged over user programmed time intervals, Total mass for fixed time intervals, Stream temperature
Calibration Routines: Sensor self-tuning with optional dynamic auto-zeroing routines; Adjustable gain on concentration and velocity measurement circuitry; Adjustable signal filtering on concentration measurement circuitry; Adjustable sampling rate for a wide range of process conditions
Software and fully installed PC available
Sensor connections designed intrinsically safe
Each sensor has Four 4-20mA outputs which are independently
programmable to any Four of 12 available parameters
MODBUS over RS485 or Ethernet communications: communication or data read out for remote parameter adjustment, calibration and testing.
Various digital and analog inputs optionally available
Benefits
Continuous analysis with selectable time averaging
No moving parts, unaffected by vibration
No additional pressure drop
Selectable output scaling
Designed intrinsically safe
Ruggedized for the factory environment
Instantaneous and average mass flow outputs
Non-contact measurement
MFM6100




















井冈山市|
仁寿县|
泰安市|
徐汇区|
百色市|
夏邑县|
谷城县|
阿城市|
长泰县|
乌海市|
邹城市|
白河县|
西吉县|
阳西县|
出国|
柳州市|
尉犁县|
邵阳县|
西乌珠穆沁旗|
海门市|
瓮安县|
文安县|
嘉荫县|
绵竹市|
五台县|
玉林市|
闸北区|
嘉义县|
霍林郭勒市|
福州市|
全南县|
石城县|
灌南县|
佛冈县|
隆德县|
长兴县|
若尔盖县|
梁平县|
于都县|
祁连县|
饶平县|